  data sheet differential pressure (flow) transmitter the fcxa 2 differential pressure (flow) transmitter accu- rately measures differential pressure, liquid level, gauge pressure or flow rate and transmits a proportional 4 to 20ma signal. the transmitter utilizes a unique micromachined capacitance silicon sensor with state-of-the-art micropro- cessor technology to provide exceptional performance and functionality. features 1. high accuracy 0.07% 0.07% accuracy is a standard feature. fuji? micro-capacitance silicon sensor assures this ac- curacy for all elevated or suppressed calibration ranges without additional adjustment. 2. minimum environmental influence the ?dvanced floating cell?design which protects the pressure sensor against changes in temperature, static pressure, and overpressure substantially reduces total measurement error in actual field applications. 3. fuji/hart bilingual communications protocol and foundation fieldbus and profibus compatibil- ity fcxa 2 series transmitter offers bilingual communi- cations to speak both fuji proprietary protocol and hart . any hart compatible devices can communi- cate with fcxa 2 . further, by upgrading electronics foundation fieldbus and profibus are also avail- able. 4. application flexibility various options that render the fcx? 2 suitable for almost any process applications include. analog indicator at either the electronics side or ter- minal side full range of hazardous area approvals built-in rfi filter and lightning arrester 5-digit lcd meter with engineering unit stainless steel electronics housing wide selection of materials 5. programmable output linearization function in addition to linear and square root, output signal can be freely programmable. (up to 14 compensated points at approximation.) 6. burnout current flexibility (under scale: 3.2 to 3.8ma, over scale: 20.8 to 21.6ma) burnout signal level is adjustable using model fxw hand held communicator (hhc) to comply with namur ne43. 7. dry calibration without reference pressure thanks to the best combination of unique construction of mechanical parts (sensor unit) and high performance electronics circuit (electronics unit), reliability of dry calibration without reference pressure is at equal level as wet calibration. fk c 11 fk c 22 fk c 23 fk c 25 fk c 26 fk c 33 fk c 35 fk c 36 fk c 38 fk c 43 fk c 45 fk c 46 fk c 48 ?.1 to + 3.2 {? to + 32} ?.1 to + 10 {? to + 100 } ?.1 to + 10 {? to + 100 } ?.1 to + 10 {? to + 100 } ?.1 to + 10 {? to + 100 } ?.1 to + 16 {? to + 160 } ?.1 to + 16 {? to + 160 } ?.1 to + 16 {? to + 160 } ?.1 to + 16 {? to + 160 } ?.1 to + 42 {? to + 420 } ?.1 to + 42 {? to + 420 } ?.1 to + 42 {? to + 420 } ?.1 to + 30 {? to + 300 } +/ 1 { +/ 10 } +/ 6 { +/ 60 } +/ 32 { +/ 320 } +/ 130 { +/ 1300 } +/ 500 { +/ 5000 } +/ 32 { +/ 320 } +/ 130 { +/ 1300 } +/ 500 { +/ 5000 } +/ 3000 { +/ 30000 } +/ 32 { +/ 320 } +/ 130 { +/ 1300 } +/ 500 { +/ 5000 } +/ 3000 { +/ 30000 } 0.1 {1} 0.1 {1} 0.32 { 3.2 } 1.3 {13} 5 {50} 0.32 { 3.2 } 1.3 {13} 5 {50} 30 { 300 } 0.32 { 3.2 } 1.3 {13} 5 {50} 30 { 300 } 1 {10} 6 {60} 32 { 320 } 130 { 1300 } 500 { 5000 } 32 { 320 } 130 { 1300 } 500 { 5000 } 3000 { 30000 } 32 { 320 } 130 { 1300 } 500 { 5000 } 3000 { 30000 } min. type range limit [kpa] {m bar} static pressure [mpa] {bar} span limit [kpa] {m bar} remark : to minimize environmental influence, span should be greater than 1/40 of the max. span in most applications. max. fkc ... 4 specifications functional specifications service: liquid, gas, or vapour static pressure, span, and range limit: lower limit of static pressure (vacuum limit) ; silicone fill sensor: see fig. 1 fluorinated fill sensor: 66kpa abs (500mmhg abs) at temperature below 60 c the maximum span of each sensor can be converted to different units using factors as below. 1mpa =10 3 kpa=10bar=10.19716kgf/cm 2 =145.0377psi 1kpa=10mbar=101.9716mmh 2 o=4.01463inh 2 o date EDSX6-114J mar. 7, 2007
fkc ... 4 2 over range limit: to maximum static pressure limit output signal: 4 to 20ma dc (linear or square root) with digital signal superimposed on the 4 to 20ma signal power supply: transmitter operates on 10.5v to 45v dc at transmitter terminals. 10.5v to 32v dc for the units with op- tional arrester. load limitations: see figure below note: for communication with hhc (1) (model: fxw), min. of 250 ? required. hazardous locations: 2000 [ ? ] 1500 1000 load resistance 500 250 0 1533 ? 600 ? operating area 24v 45v 10 16.1 50 [ v ] 10.5v power voltage a tex ex ii 2 gd eex d iic t6 ip66/67 t85 c tamb = 40 c to +65 c eex d iic t5 ip66/67 t100 c tamb = 40 c to +85 c factory mutual class i div.1 groups b, c, d t6 type 4x class ii iii div.1 groups e, f, g t6 type 4x tamb max = +60 c csa class i div.1 groups c, d class ii div.1 groups e, f, g class iii div.1 note) ?eal not required?enclosure is allowed. tiis ex do iib+h 2 t4 tamb max = +55 c maximum process temp. = +120 c iecex scheme /saa ex d iic t5 ip66/67 pending tamb = 40 c to +85 c ex d iic t6 ip66/67 pending tamb = 40 c to +65 c authorities flameproof a tex ex ii 1 gd eex ia iic t5 tamb = 40 c to +40 c eex ia iic t4 tamb = 40 c to +80 c entity parameters: ui=28v, ii=93.3ma, pi=0.66w, ci=27nf (without arrester), ci=34.2nf (with arrester), li=1.134mh factory mutual class i ii iii div.1 groups a, b, c, d, e, f, g t4 entity type 4x entity parameters: vmax=42.4v, imax=113ma, pi=1w, ci=34.2nf, li=1.134mh csa class i div.1 groups a, b, c, d class ii div.1 groups e, f, g class iii div.1 temp code t4 tamb max = +40 c temp code t3c tamb max = +85 c entity parameters: vmax=28v, imax=93ma, ci=27nf (without arrester), ci=34.2nf (with arrester), li=1.4mh tiis ex ia iic t4 tamb max = +60 c entity parameters: ui=28v, ii=94.3ma, pi=0.66w, ci=32.6nf, li=1.134mh iecex scheme /saa ex ia iic t4 ip66/67 tamb = 40 c to +70 c ex ia iic t5 ip66/67 tamb = 40 c to +50 c entity parameters: ui=28v, ii=93.3ma, pi=0.66w, ci=0.033 f, li=1.034mh authorities intrinsic safety model code 9th digit 13th digit a,b,c,d,j y,g,n 40 c to +85 c l,p,m,1,2,3 y,g,n 20 c to +80 c q ,s,n,4,5,6 y,g,n 20 c to +60 c e,f,g,h,k y,g,n 40 c to +60 c w,a,d ?0 c to +60 c t amb
3 programmable output linearization function: output signal can be characterized with ?4 points linear approximation func- tion?from hhc (1) . emc conformity: en61326 ?utput underscale? adjustable within the range 3.2ma to 3.8ma from hhc (1) 3.8 3.2 4 20 20.8 21.6 [ma] over scale burnout probable over range probable under range normal operating range under scale burnout loop-check output: transmitter can be configured to provide constant signal 3.8ma through 21.6ma by hhc (1) . temperature limit: ambient: 40 to +85 c (?0 to +80 c for lcd indicator) ( 40 to +60 c for arrester option) (?0 to +60 c for fluorinated oil filled transmitters) for explosionproof units (flameproof or intrinsic safety), ambient tempera- ture must be within the limits speci- fied in each standard. process: 40 to +120 c for silicone fill sensor ?0 to +80 c for fluorinated oil fill sen- sor storage: 40 to +90 c humidity limit: 0 to 100% rh communication: with hhc (1) (model fxw, consult data sheet no. eds8-47), following informa- tion can be remotely displayed or recon- figured. note: hhc? version must be more than 6.0 (or fxw 1 3), for fcx- a 2 . zero/span adjustment : zero and span are adjustable from the hhc (1) . zero and span are also adjustable externally from the adjustment screw (span adjustment is not available with 9th digit code ?, p, m, q , s, n?. damping: adjustable from hhc or local adjustment unit with lcd display. the time constant is adjustable between 0.12 to 32 seconds. zero elevation/suppression: ?00% to +100% of url normal/reverse action: selectable from hhc (1) indication: analog indicator or 5-digit lcd meter, as specified. burnout direction: selectable from hhc (1) if self-diagnostic detect transmitter fail- ure, the analog signal will be driven to ei- ther ?utput hold? ?utput overscale or ?utput underscale?modes. ?utput hold? output signal is hold as the value just before failure happens. ?utput overscale? adjustable within the range 20.8ma to 21.6ma from hhc (1) (note) (1) hhc: hand held communicator vv vv v vv v vv vv vv vv vv vv ? v v vv vv vv vv items display set tag no. model no. serial no. engineering unit range limit measuring range damping linear square root burnout direction calibration output adjust data self diagnoses printer external switch lock transmitter display linearize rerange output mode a tex ex ii 3 gd eex nl iic t5 tamb = 40 c to +40 c eex nl iic t4 tamb = 40 c to +80 c specific parameters: model without arrester: ui=42.4v, ii=113ma, pi=1w, ci=27nf, li=1.134mh model with arrester: ui=32v, ii=113ma, pi=1w, ci=34.2nf, li=1.134mh eex nal iic t5 tamb = 40 c to +40 c eex nal iic t4 tamb = 40 c to +80 c specific parameters: model without arrester: umax=42.4v, imax=113ma, pmax=1w model with arrester: umax=32v, imax=113ma, pmax=1w factory mutual class i ii iii div.2 groups a, b, c, d, f, g t4 entity type 4x csa class i div.2 groups a, b, c, d class ii div.2 groups e, f, g class iii div.2 temp code t4 tamb max = +40 c temp code t3c tamb max = +85 c entity parameters: vmax=28v, ci=27nf (without arrester), ci=34.2nf (with arrester), li=1.4mh tiis iecex scheme /saa authorities t ype n nonincendive model code 9th digit 13th digit a,b,c,d,j y,g,n 40 c to +85 c l,p,m,1,2,3 y,g,n 20 c to +80 c q ,s,n,4,5,6 y,g,n 20 c to +60 c e,f,g,h,k y,g,n 40 c to +60 c w,a,d ?0 c to +60 c t amb
fkc ... 4 4 performance specifications for linear output reference conditions, silicone oil fill, 316ss isolating diaphragms, 4 to 20ma analog output in linear mode. accuracy rating: (including linearity, hysteresis, and re- peatability) max span above 32kpa model: for spans greater than 1/10 of url: 0.07% of span for spans below 1/10 of url: max span 1kpa, 6kpa model: for spans greater than 1/10 of url: 0.1% of span for spans below 1/10 of url: stability: 0.1% of upper range limit (url) for 3 years for 6th digit code 3, 5, 6, 8. temperature effect: effects per 28 c change between the limits of ?40 c and +85 c range code (6th digit in code symbols) ??1kpa {10mbar} max. span ??6kpa {60mbar} max. span ??32kpa {320mbar} max. span ??130kpa {1300mbar} max. span ??500kpa {5000mbar} max. span ??3000kpa {30000mbar} max. span url span url span total effect zero shift overrange effect: 0.1 url span 0.02+0.05 % of span ( ) static pressure effect: 0.1 url span 0.05+0.05 % of span () supply voltage effect: less than 0.005% of calibrated span per 1v rfi effect: less than 0.2% of url for the frequen- cies of 20 to 1000mhz and field strength 30 v/m when electronics covers on. (classification: 2-abc: 0.2% span per sama pmc 33.1) update period: 120 msec * ) step response: (without electrical damping) 0.125+0.1 % 0.15+0.1 % url span () () url span 0.075+0.0125 % 0.095+0.0125 % mounting position effect: zero shift, less than 0.12kpa {1.2m bar} for a 10 tilt in any plane. no effect on span. this error can be corrected by adjusting zero. dielectric strength: 500v ac, 50/60hz 1 min., between cir- cuit and earth. insulation resistance: more than 100m ? at 500v dc. turn-on time: 4 sec. internal resistance for external field indicator: 12 ? or less ( )( ) static pressure code (5th digit in code symbols) ??/ 1kpa{10m bar} sensor ??/ 6kpa{60m bar} sensor ? ? ? 0.3% / 1mpa {10bar } 0.1% / 3.2mpa {32bar } 0.1% /10mpa {100bar } 0.1% /16mpa {160bar } 0.25% /42mpa {420 bar} zero shift (% of url) 0.2 s range code time constant* ) dead time* ) (6th digit in code symbols) 0.8 s 0.5 s 0.3 s 0.2 s ? ? ? ??through ? *) faster response is available as option (maximum update rate: 25 times per second). static pressure code (5th digit in code symbols) ??/1kpa {10m bar} sensor ??/6kpa {60 m bar} sensor ? ? ? zero shift (% of url) 0.05%/10mpa{100bar} 0.2% / 1mpa{10bar} 0.2% / 3.2mpa{32bar} performance specifications for square root output accuracy rating: temperature effect: effects per 55 c change between the lim- its of 40 c and +85 c low flow cut-off: customer configurable for any point be- tween 0 to 20% of output max span 1kpa, 6kpa model: 0.24+0.03125 %/28 c ( ) () range code shift at 20% output point ??and ? ??through ? 0.375+0.25 %/28 c url span url span output accuracy 50 to 100% 20 to 50% 10 to 20% 0.1 % 0.25% 0.5 % 50 to 100% 20 to 50% 10 to 20% 0.07 % 0.175 % 0.35 % span output (0.02+0.05 0.1 url/span)% 2.5 (0.02+0.05 0.1 url/span)% 5 (0.02+0.05 0.1 url/span)% below 0.1 url over 0.1 url
5 note: (* 1 ) scs14a per jis g 5121 (equivalent cf8m per astm a351/a351m) remarks: sensor o-rings: viton o-ring and teflon gasket select- able. availability of above material design depends on ranges and static pressure. refer to ?ode symbols? non-wetted parts material: electronics housing: low copper die-cast aluminum alloy finished with epoxy/ polyurethane double coating (stan- dard), or 316 stainless steel (scs14a per jis g5121), as specified. bolts and nuts: cr-mo alloy (standard), 304 stainless steel (for static pressure code ?? ?? and ??only), or 630 stainless steel (for static pressure code ??and ??only). static pres- sure rating for code ??with 304 stainless steel bolts is degraded to 10mpa. fill fluid: silicone oil (standard) or fluori- nated oil mounting bracket: 304 stainless steel environmental protection: iec ip67 and nema 6/6p mounting: on 60.5mm(jis 50a) pipe using mount- ing bracket, direct wall mounting, or di- rect process mounting. mass{weight}: transmitter approximately 4.4kg without options. add; 0.5kg for mounting bracket 0.8kg for indicator option 4.5kg for stainless steel housing option optional features indicator: a plug-in analog indicator (2.5% accu- racy) can be housed in the electronics compartment or in the terminal box of the housing. an optional 5-digit lcd meter with engi- neering unit is also available. local adjustment unit with lcd display: an optional 5-digit lcd meter with zero/ span adjustment function, loop-check function and damping adjustment func- tion, is available. arrester: a built-in arrester protects the electron- ics from lightning surges. lightning surge immunity: 4kv (1.2 50 s) oxygen service: special cleaning procedures are followed throughout the process to maintain all process wetted parts oil-free. the fill fluid is fluorinated oil. chlorine service: the fill fluid is fluorinated oil. degreasing: process-wetted parts are cleaned, but the fill fluid is standard silicone oil. not for use on oxygen or chlorine measure- ment. nace specification: metallic materials for all pressure bound- ary parts comply with nace mr-01-75. astm b7m or l7m bolts and 2hm nuts (class ii) are available. static pressure rating for code ??(16 mpa) is degraded to 10mpa. vacuum service: special silicone oil and filling procedure are applied. see fig. 1. optional tag plate: an extra stainless steel tag with cus- tomer tag data is wired to the transmit- ter. coating of cell: cell? surface is finished with epoxy/ polyurethane double coating. specify if environment is extremely corrosive. physical specifications electrical connections: g1/2, 1/2-14 npt, pg13.5, or m20 1.5 conduit, as specified. and 1 conduit or 2 conduits, as specified. process connections: 1 / 4 -18 npt or rc 1 / 4 on 54mm centers, as specified. meets din 19213. process-wetted parts material: ?0 60 ?5 85 120 none-operating area 2.7 {27} 4 {40} 20 operating pressure process temperature[ c ] {200} 101 {1010} [kpa abs] {mbar abs} silicone oil (code:y,g,n) silicone oil (code:r) operating area fig. 1 relation between process temperature and operating pressure v h j m t b l u 316 stainless steel hastelloy-c lining 316 stainless steel monel lining tantalum lining hastelloy-c lining monel lining tantalum lining 316/316l stainless steel 316/316l stainless steel 316/316l stainless steel 316/316l stainless steel 316/316l stainless steel hastelloy-c monel hastelloy-c 316l stainless steel hastelloy-c 316l stainless steel +au coating monel tantalum hastelloy-c monel tantalum 316 stainless steel(* 1 ) 316 stainless steel(* 1 ) 316 stainless steel(* 1 ) 316 stainless steel(* 1 ) 316 stainless steel(* 1 ) hastelloy-c lining monel lining tantalum lining material code (7th digit in code symbols) process cover diaphragm wetted sensor body vent/drain
fkc ... 4 6 accessories oval flanges: (model ffp, refer to data sheet no. eds6-10) converts process connection to 1 / 2 -14 npt or to rc 1 / 2 ; in carbon steel or in 316 stainless steel. equalizing valves: (model ffn, refer to data sheet no. eds6-10) available in carbon steel or in 316 stain- less steel and in pressure rating 16mpa or 42mpa. hand-held communicator: (model fxw, refer to data sheet no. eds 8-47) z/s board: parts no.=zzpfcx4-a070 when z/s board is mounted on the fcx a 2 amplifier unit, external adjustment screw will be available for zero and span adjustment. ordering information when ordering this instrument, specify: 1. code symbols 2. measuring range 3. output orientation (burnout direction) when abnormal- ity is occurred in the transmitter. hold / overscale (21.6ma) / underscale (3.2ma) unless otherwise specified, output hold function is sup- plied. 4. output mode (linear or square root output) unless otherwise specified, output mode is linear. 5. indication method (indicated value and unit) in case of the actual scale (code d, h, p, s on 9th digit). 6. tag no. (up to 26 alphanumerical characters), if required.
7 code symbols a b c d e s t v w x description note note 1 note 1 note 1 note 1 note 2 digit 4 5, 6, 7 process connection rc 1 /4 1 /4 -18npt 1 /4 -18npt 1 /4 -18npt 1 /4 -18npt rc 1 /4 1 /4 -18npt 1 /4 -18npt 1 /4 -18npt 1 /4 -18npt static pressure [mpa] {bar} ?.1 to +3.2 {? to+32} ?.1 to+10 {? to 100} ?.1 to+16 {? to+160} ?.1 to+42 {? to+420} ?.1 to+30 {? to+300} ?.1 to+10 {? to+100} 4567 123 f4 kc 89 10 11 12 13 14 15 digit no. of code note 1: (*1) the thread is m12, if 42mpa {420bar} static pressure is specified. note 2: (*2) 100: 1 turn down is possible, but should be used at the span greater than 1/40 of the maximum span for better performance. 11v 11j 11h 22v 22j 22h 33v 33j 33h 33m 33t 35v 35j 35h 35m 35t 36v 36j 36h 36m 36t 38v 38j 43v 43j 43h 43m 45v 45j 45h 45m 46v 46j 46h 46m 48v 48j 23b 23l 23u 25b 25l 25u 26b 26l 26u oval flange screw 7 /16 -20unf 7 /16 -20unf m10 (or m12)(*1) m10 (or m12)(*1) 7 /16 -20unf 7 /16 -20unf 7 /16 -20unf m10 (or m12)(*1) m10 (or m12)(*1) 7 /16 -20unf conduit connection g 1 /2 ( 1) 1 /2 -14npt ( 1) pg 13.5 ( 1) m20 1.5 ( 1) pg 13.5 ( 1) g 1 /2 ( 2) 1 /2 -14npt ( 2) pg 13.5 ( 2) m20 1.5 ( 2) pg 13.5 ( 2) span limit (*2) [kpa] (m bar) 0.1? {1?0} 0.1? {1?0} 0.32?2 {3.2?20} 1.3?30 {13?300} 5?00 {50?000} 30?000 {300?0000} 0.32?2 {3.2?20} 1.3?30 {13?300} 5?00 {50?000} 30?000 {300?0000} 0.32?2 {3.2?20} 1.3?30 {13?300} 5?00 {50?000} process cover 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel hast. c lining monel lining tantalum lining hast. c lining monel lining tantalum lining hast. c lining monel lining tantalum lining diaphragm 316l stainless steel 316l stainless steel +au coating hast. c 316l stainless steel 316l stainless steel +au coating hast. c 316l stainless steel 316l stainless steel +au coating hast. c monel tantalum 316l stainless steel 316l stainless steel +au coating hast. c monel tantalum 316l stainless steel 316l stainless steel +au coating hast. c monel tantalum 316l stainless steel 316l stainless steel +au coating 316l stainless steel 316l stainless steel +au coating hast. c monel 316l stainless steel 316l stainless steel +au coating hast. c monel 316l stainless steel 316l stainless steel +au coating hast. c monel 316l stainless steel 316l stainless steel +au coating hast. c monel tantalum hast. c monel tantalum hast. c monel tantalum wetted cell body 316 stainless steel 316 stainless steel hast. c lining 316 stainless steel 316 stainless steel hast. c lining 316 stainless steel 316 stainless steel hast. c lining monel lining tantalum lining 316 stainless steel 316 stainless steel hast. c lining monel lining tantalum lining 316 stainless steel 316 stainless steel hast. c lining monel lining tantalum lining 316 stainless steel 316 stainless steel 316 stainless steel 316 stainless steel hast. c lining monel lining 316 stainless steel 316 stainless steel hast. c lining monel lining 316 stainless steel 316 stainless steel hast. c lining monel lining 316 stainless steel 316 stainless steel hast. c lining monel lining tantalum lining hast. c lining monel lining tantalum lining hast. c lining monel lining tantalum lining combination with 12th digit code "c, e, p, q " are not available. 21
fkc ... 4 8 description note note 3 note 3 note 4 digit 9 10 11 12 13 14 4567 123 f4 kc 89 10 11 12 13 14 15 digit no. of code note 3: (*3) in case of square root output mode, square root scale is not available. note 4: (*4) customer tag number can be engraved on standard stainless steel name plate. if extra tag plate is required, select ?es? a b c d e x r g h j k p t v a c d f y b c e m n p q y w g a d n r a b c d j e f g h k l p m q s n 1 2 3 4 5 6 a b specify ??or ??for the 7th digit code ?? ?? or ? (*4) indicator arrester none none analog, 0 to 100% linear scale none analog, 0 to 100% sq. root scale none (*3) analog, custom scale none analog, double scale (linear and sq. root) none none yes analog, 0 to 100% linear scale yes analog, 0 to 100% sq. root scale yes (*3) analog, custom scale yes analog, double scale (linear and sq. root) yes digital, 0 to 100% none digital, custom scale none digital 0 to 100% square root none digital, 0 to 100% yes digital, custom scale yes digital 0 to 100% square root yes digital, 0 to 100% (local adjustment unit with lcd display) none digital, custom scale (local adjustment unit with lcd display) none digital, 0 to 100% square root (local adjustment unit with lcd display) none digital, 0 to 100% (local adjustment unit with lcd display) yes digital, custom scale (local adjustment unit with lcd display) yes digital, 0 to 100% square root (local adjustment unit with lcd display) yes none (for ordinary locations) tiis, flameproof (conduit seal) (available for 4th digit code ?? ?? tiis, flameproof (cable gland seal) (available for 4th digit code ?? ?? fm, flameproof (or explosionproof) (available for 4th digit code ?? ?? csa, flameproof (or explosionproof) (available for 4th digit code ?? ?? atex, flameproof iecex scheme/saa, flameproof (approval pending) tiis, intrinsic safety fm, intrinsic safety and nonincendive csa, intrinsic safety and nonincendive atex, intrinsic safety atex, type n iecex scheme/saa, intrinsic safety fm, combined of flameproof and intrinsic safety vent/drain mounting bracket standard none standard yes, stainless steel side none side yes, stainless steel extra ss tag plate stainless steel elec, housing coating of cell none none none yes none none none yes none yes yes none none none yes yes none yes none yes yes yes yes yes treatment fill fluid standard silicone oil standard fluorinated oil degreasing silicone oil oxygen service fluorinated oil (7th digit code ?? ??only) chlorine service fluorinated oil (7th digit code ?? ?? ?? ?? nace specification silicone oil (not available for 7th digit code ?? ??and 15th digit code ?? ?? vacuum service silicone oil for vacuum use viton (o-ring) teflon (gasket) z/s board attached. 21
9 description note note 8 note 5 note 6 note 7 note 9 digit 15 4567 123 f4 kc 89 10 11 12 13 14 15 digit no. of code note 5: (*5) static pressure should be ?.1 to +10mpa{? to +100bar}. note 6: (*6) available for 5th digit code ?? ?? ?? in case of stainless steel bolt with 5th digit code ?? static pressure should be ?.1 to +10mpa {? to + 100bar}. note 7: (*7) available for 5th digit code ?? ?? note 8: (*8) in case of tropical use, select stainless bolts and nuts. note 9: (*9) if other option is not necessary, 21st digit code is blank. in case of 21st digit code is blank, instruction manual attached. a b c d e f (*5) (*6) (*7) (*8) cr-mo alloy hexagon socket head cap screw/carbon steel nut cr-mo alloy hexagon bolt/nut nace bolt/nut (astm a193 b7m/a194 2hm) nace bolt/nut (astm a320 l7m/a194 2hm) 304 stainless steel bolt/304 stainless steel nut 630 stainless steel bolt/304 stainless steel nut 21 21 (*9) instruction manual unattached l
fkc ... 4 10 outline diagram (unit:mm) < 7th digit code : v, h, m, t, j > d 4th digit of the code symbols conduit conn. press. conn. oval flange screw ef h g1/2 17 8 rc1/4 7/16-20unf screw depth15 3, 4, a, s 1/2-14npt 16 5 1/4-18npt 7/16-20unf screw depth15 b, t pg13.5 8 4.5 1/4-18npt m10 screw depth15 c, v m20 1.5 16 5 1/4-18npt m10 screw depth15 d, w pg13.5 8 4.5 1/4-18npt 7/16-20unf screw depth15 e, x table 1 note 1) cable gland is supplied in case of flamproof packing type. ?1 cable is suitable. note 2) the pressure connector is located on the down side surface of the detector, when the vent/drainplug is attatched on the upper side of the detector (when the 21th digit of the code symbols: c, e or d). ck ck connection diagram 17 g 1/2 ?3 d e f ?5 h ? 8 2.5 ?8.5 see table 1 see table 1 detail "b" detail "c" (conduit conn.) detail "a" (press. conn.) (27) 38 58 37 210 70 41 ?0 105 52.5 94.5 88 120 43.5 ?0 154 59 43 231 mtg. pipe jis 50a (2b) u-bolt m8 "a" press. conn. zero adj. screw fastener (flameproof only) cable gland (option) "c" conduit conn. "b" conduit conn. vent/drain plug 4 holes 9 dia. earth terminal oval flange screw see table 1 press.conn. (high pressure side) with field ind. up 70 104 press.conn. (low pressure side) 41.3 side vent (option) 8 105 10 130 54 4-m8 12 in case of 4th digit code "t" in case of 4th digit code "a.b.c.d.e" in case of 4th digit code "s.v.w.x" vent/drain plug (when the vent/drain plug attatched on the upper side of the detector) down note 2) note 1) electronics unit sensor unit
11 table 1 4th digit of the code symbols conduit conn. oval flange screw efh g1/2 17 8 7/16-20unf screw depth10 3, 4, a, s 1/2-14npt 16 5 7/16-20unf screw depth10 b, t pg13.5 8 4.5 m10 screw depth10 c, v m20 1.5 16 5 m10 screw depth10 d, w pg13.5 8 4.5 7/16-20unf screw depth10 e, x note 1) cable gland is supplied in case of flamproof packing type. ?1 cable is suitable. detail "d" detail "c" (conduit conn.) detail "a" (press. conn.) detail "b" (press. conn) 17 g 1/2 ?3 e f h ?5 2 +0.2 +0.1 ?6 ?2 0 -0.1 1 ? 4th digit code "a, s" see table 1 ck ck connection diagram ? ?6 1 /4-18npt 10 4th digit code "b, c, d, e, t, v, w, x" 94.5 in case of 4th digit code "t" in case of 4th digit code "a.b.c.d.e" up 105 10 in case of 4th digit code "s.v.w.x" down (27) 213 40 58 38 70 234 41.3 70 104 ?0 u-bolt m8 120 ?0 fastener (flameproof only) "d" conduit conn. 186 91 43 press.conn. (high pressure side) mtg. pipe jis 50a (2b) "a"or"b" press. conn. oval flange screw see table 1 zero adj. screw 105 52.5 88 vent/drain plug "c" conduit conn. with field ind. 4 holes 9 dia. earth terminal press.conn. (low pressure side) 8 54 4-m8 12 cable gland (option) 41 electronics unit sensor unit note 1) < 7th digit code : b, l, u >
fkc ... 4 information in this catalog is subject to change without notice. printed in japan head office gate city ohsaki, east tower, 11-2, osaki 1-chome, shinagawa-ku, tokyo 141-0032, japan http://www.fesys.co.jp/eng instrumentation div. international sales dept. no.1, fuji-machi, hino-city, tokyo, 191-8502 japan phone: 81-42-585-6201, 6202 fax: 81-42-585-6187 http://www.fic-net.jp/eng caution on safety *before using this product, be sure to read its instruction manual in advance. the product conforms to the requirements of the electromagnetic compatibility directive 94/9/ec as detailed within the technical construction file number tn513035. the applicable standards used to demonstrate compliance are : frequency range mhz limits reference standard 30 to 230 40db ( v/m) quasi peak, measured at 10m distance 230 to 1000 47db ( v/m) quasi peak, measured at 10m distance cispr16-1 and cispr16-2 phenomenon test value basic standard performance criteria b electrostatic discharge conducted rf 0.15 to 80mhz 3v 80%am (1khz) electromagnetic field 4kv (contact) 8kv (air) 80 to 1000mhz 10v/m 80%am (1khz) en61000-4-2 burst a en61000-4-3 rated power frequency magnetic field 30a/m 50hz a en61000-4-8 2kv 5khz b en61000-4-4 surge 1.2 s/50 s 1kv (line to line) 2kv (line to ground) b en61000-4-5 a en61000-4-6 emi (emission) en61326 : 1997 class a (standard for industrial location) emi (immunity) en61326: 1997 annex a (standard for industrial location) note) definition of performance criteria a: during testing, normal performance within the specification limits. b: during testing, temporary degradation, or loss of function or performance which is self-recovering.


▲Up To Search▲   

 
Price & Availability of EDSX6-114J

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X